Back to Help Center ChemrytHPLC Help

HPLC Chromatogram Predictor

Method-specific retention prediction, gradient planning, metrics, and integration payload review.

Prerequisite: Load The Molecule From ChemrytIQ

Before opening ChemrytHPLC, search the molecule in ChemrytIQ by SMILES, InChI, molecule name, or CAS number. Confirm the correct molecule on the ChemrytIQ page, then open the required Chemryt app from that same molecule context so the selected structure is loaded into the app automatically.

What ChemrytHPLC Does

ChemrytHPLC supports molecule drawing, SMILES or molfile input, method metadata, method optimization, gradient controls, backpressure guardrails, predicted chromatograms, chromatographic metrics, and future-ready integration objects.

Prediction target

Analyze a single compound or mixture and review molecule descriptors before prediction.

Method metadata

Capture method template, column chemistry, brand, mobile phases, additive, and chromatographic mode.

Optimization

Tune objectives, gradient controls, instrument guardrails, method notes, and chromatographic metrics.

Quick Workflow

  1. Load the molecule from the editor, SMILES field, molfile import, example list, or ChemrytIQ transfer.
  2. Select the prediction target mode and fill in method metadata such as column chemistry, mobile phases, additive, pH, and mode.
  3. Use method optimization controls when you need to balance runtime, resolution, robustness, and pressure.
  4. Preview the gradient and estimated backpressure profile before running the final prediction.
  5. Run the prediction and review retention, method interpretation, chromatogram, and metrics dashboard.
  6. Copy or export the integration object when another workflow needs the method-specific payload.

Main Areas

AreaWhat to enter or reviewWhen to use it
Input Molecule editor, SMILES, molfile, examples, mixture components, and descriptors. Use to prepare the chemical target.
Method Template, column, mobile phases, additive, mode, pH, gradient, pressure, and instrument guardrails. Use to model the HPLC method realistically.
Results Predicted retention, chromatogram, metrics dashboard, notes, warnings, and integration object. Use to decide whether the method is ready for lab scouting.

Tutorial Notes

  • Choose reversed-phase, HILIC, ion-exchange, or another mode based on analyte polarity and ionization behavior.
  • Check buffer capacity and sample-solvent mismatch warnings before trusting a retention trend.
  • Use a gradient preview for complex mixtures and a simpler isocratic setup for quick single-compound scouting.
  • Treat predicted pressure as a guardrail, then verify on the actual instrument and column hardware.

ML Model / Computation Used

Model or methodWhat it predictsImplementation details
ChemrytHPLC retention-time baseline Method-specific retention time in minutes. Hybrid scaffold-split models use RDKit descriptors, Morgan fingerprints, and method features. Routes include RepoRT, SMRT, and mixed joblib models; manifest metrics include MAE about 1.29-1.74 min and R2 about 0.73-0.79.
Frontend chromatogram simulation Peak width, intensity, tailing, baseline, secondary peaks, and visualization. These are simulation outputs around the retention prediction, not separate trained retention models.

Good Practice

HPLC predictions help plan methods, but final method acceptance requires standards, suitability injections, robustness checks, and validated instrument conditions.

Reference Used

This Tutorial page was prepared from the ChemrytLabs reference module: ChemrytHPLC.

Centralized Chemryt tutorial documentation. Validate critical scientific or safety decisions with experimental evidence.